Difference between Star and Delta ConnectionAs we know that Star & Delta Connection only possible in 3 phase system, so in our domestic system it is not poss
For example, the Wye connection requires fewer turns than the Delta connection (1.732:2) to achieve the same electrical characteristics. This makes machine winding smaller motors with narrow stator slots easier. On the other hand, a portion of the leads in a dual-voltage, Delta connection can be a smaller diameter than those of a Wye.
Note, that in the delta connection to line current is √3 times the phase current, whereas in the open delta, they are the same. The transformer output power (in VA) is for a balanced transformer system for the closed delta connection (using phase current), this give: V A = 3 V L I p h. And for the open delta connection: V A = 3 V L I p h
A Wye (Y) connection is a four-phase wiring configuration that typically consists of four legs connected together to form a star. This type of connection is often used when four windings are present in an electrical system, such as in transformers and generators. Unlike the Delta connection, the current flows from one leg of the star to the
Vector Groups are the IEC method of categorizing the primary and secondary winding configurations of 3-phase transformers. Windings can be connected as delta, star, or interconnected-star ( zigzag ). Winding polarity is also important, since reversing the connections across a set of windings affects the phase-shift between primary and secondary.
Star to Delta Conversion and Delta to Star Conversion. The typical three-phase networks use two main methods by names which specify the way in which resistances are allied. . In a star connection of the network, the circuit can be connected in symbol ‘∆’ model, similarly in a delta connection of the network; the circuit can be connected in symbol ‘∆
Star-delta starting. Some motors can be started using the star-delta method: the motor is first connected in ‘star’ configuration, i.e. the current flows through 2 motor windings in series, reducing the applied voltage. This allows the motor to gather speed without drawing excessive current.
I need it be installed on ~3, 230V and I need to calculate the line current to choose proper circuit breaker. The resistance of every heating element is 13Ω. According to the calculation I did the power remains the same but the line current will increase to 30A. Delta: I (phase) = 230V / 13Ω = 17,5A.